PRODUCT DATA (cont)
PERFORMANCE AND ELECTRICAL DATA
MODEL 52SC (230/208V)
MODEL
NO.
COOLING
CAPACITY*
(Btuh)
EER
VOLT
RANGE
AMPS
COOLING
WATTS
COOLING
POWER
FACTOR
%
52SCD007---3 7,100/ 7,000 11.0/11.1 253-198 2.8/3.0 645/628 97
52SCE009---3 9,100/ 9,100 9.3/ 9.3
253-187
4.4/4.6 979/979 97
52SCD012---3 11,800/11,600 9.0/ 9.0 5.9/6.3 1,310/1,288 98
52SCC014---3 13,500/13,200 8.8/ 8.8 253-198 6.8/7.3 1,530/1,500 98
MODEL
NO.
FAN MOTOR
Horsepower
Full Load
Amps
Indoor CFM
HI/LO
52SCD007---3 1/15 0.6 280/200
52SCE009---3 1/8 0.78 350/300
52SCC012---3 1/6 1.0 380/310
52SCC014---3 1/8 0.78 350/300
MODEL
NO.
MAX. FUSE
SIZE
(AMPS)
MIN.
CIRCUIT
AMPS
RECEPTACLE
TYPE
R-22
CHARGE
(oz)
DEHUMIDIFICATION
(Pints/Hr)
APPROX.
CHASSIS
SHIP WT.
(lb)
52SCD007---3
15
5.0
A
23 1.3 125
52SCE009---3 6.7 27 2.1 120
52SCD012---3 7.4 36 3.3 129
52SCC014---3 10.5 35 4.3 130
LEGEND
EER — Energy Efficiency Ratio
*Rated in accordance with ARI Standard 310/380-93.
RECEPTACLES AND FUSE TYPES
UNIT NAMEPLATE VOLTAGE 230/208
OUTLET RATED VOLTS/AMPS 250/15 250/20 250/30
OUTLET BLADE
CONFIGURATION
A
B
C
FEMALE RECEPTACLE
MFG. PART NO.
Hubbell
P&S
GE
Arrow-Hart
5661
5661
GE4069-1
5661
5461
5871
GE4182-1
5861
9330
5930
GE4139-3
5700
TIME-DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
15 20* 30
LEGEND
HACR — Heating, Air Conditioning, Refrigeration
*May be used for 15-amp applications if fused for 15 amps.