Test Descriptions
TEST_16 - RXA Audio Distortion
TEST_16 - RXA Audio Distortion
Description
This test measures the distortion from the receiver when a standard
test tone is applied to the radio.
NOTE
Audio connections from the radio to the test system are required for this
test.
Also, this test uses the C-Message audio filter or the CCITT audio filter
if it is installed in the test system.
•A
50 dBm RF signal is applied to the receiver’s antenna.
•The
50 dBm RF signal is modulated to deviate to 8 kHz at a 1 kHz
rate with a6000 Hz SAT tone present.
Narrow analog operation uses 3 kHz deviation and DSAT.
Pass/Fail Limits Used
1. RXA Audio Distortion (%)
Parameters Used
1. CPA Control Channel [1-799 or 991 -1023]
2. CPA DSAT Vector
3. CPA Enter Ph# [0=If Needed,1=Always,Here]
4. CPA MIN From? [0=RECC,1=All 0’s,2=Phone #]
5. CPA Prt RECC RVC Data [0=no 1=yes 2=fail]
6. CPA SAT Tone (Hz)
14. RC Compandor is Always On [0=no 1=yes]
22. RX RF Level for Signaling (dBm)
31. RXA Set Audio Lvl [0=no xx=level volts]
32. RXA Tolerance for Setting Audio Level (% error)
49. TXA TS Atten for Signaling [0, 20, 40] (dB)