1-7 62-02575-07
Table 1-3. Temperature Controller Events -- Continued
Event When Event Occurs Data Sent Limits
Trip Start (TS)
Any time trip start is en-
tered
NA NA
USDA Trip Comment
When entered with
interrogation device
Up to 80 bytes of custom-
er comment data
Last 1 per day
Pre-Trip Data
Any time a Pre-T rip test is
completed and Controller
is configured to send indi-
vidual test data
Pass/Fail for each sub-test,
and appropriate data points
for each test
Unlimited
Economy Mode Start
(ECON_S)
Any time economy mode
is initiated
NA NA
Economy Mode End
(ECON_E)
Any time economy mode
is terminated.
NA NA
ISO Trip Comment
Changed
Whenever entered Data entered by user
Last 1 per hour, last 1 per
day
Bulb Mode Start
(BULB_S)
Any time bulb mode starts
Evaporator fan speed,
DTT opening temperature,
dehumidification set point
NA
Bulb Mode End
(BULB_E)
Any time bulb mode ends NA NA
Controller Configuration
Change
Whenever changed by user Configuration information
Last 1 per hour, last 1 per
day
Operating Mode Change
Whenever unit changes
mode
New operating mode
Last 2 per hour, last 24 per
day
Power Management
Start
(Reciprocating Only)
Whenever power manage-
ment starts
Power management mode
Last 4 per hour, last 24 per
day
Power Management End
(Reciprocating Only)
Whenever power manage-
ment ends
Method used to end power
management
Last 4 per hour, last 24 per
day
Airslide Position
Change
(Reciprocating Only)
Whenever Makeup Vent
Slide Position is changed
Source of change com-
mand
Last 1 per hour, last 6 per
day
Phase Switching
(Scroll Only)
Whenever Phase Sequence
is Checked
Phase switched to correct/
incorrect
Last 6 per hour, last 24 per
day
Table 1- 4 DataCORDER Events
Event
When Event Occurs Data Stored Limits
Case 1: Whenever an
alarm changes state
Case 1: Alarms active
during this hour
Case 1: 1 per hour which
is a combination of all
events in that hour
DataCORDER Alarm Ac-
tivity (DAL)
Case 2: At the end of any
hour where an alarm ac-
tive during that hour is in-
active at the end of the
hour
Case 2: Currently active
alarms
Case 2: 1 per hour
Battery Backup Start
(OFFWB)
Loss of main power with
battery pack present
NA NA
Battery B ackup End
(ONWB)
Restoration of AC power
with battery pack present
NA NA
Power Loss (OFF)
Loss of AC power with no
battery pack present
NA NA