Carrier 50PG03-16 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro ne Carrier 50PG03-16. Installation Instructions [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 4
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC 111 Catalog No. 534-80246 Printed in U.S.A. Form 48/50PG-22SI Pg 1 8-05 Replaces: New
Book1144
Tab 1a1b6a6b
Installation Instructions
Part Numbers: CRADCURB001A00, CRADCURB002A00, CRADCURB003A00
PACKAGE USAGE
*Roof curbs CRRFCURB022A00 and CRRFCURB023A00 are COBRA™ full perimeter roof curbs. The accessory roof curb adapters will work with
these curbs.
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform the basic maintenance
functions of replacing filters. All other operations should be
performed by trained service personnel. When working on air-
conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit, and other safety precautions
that may apply.
GENERAL
The accessory roof curb adapter is used when retrofitting a
48/50PG unit onto an existing Carrier roof curb. The roof curb
adapter mounts on existing DJ, HJ, TF, TJ, TM roof curbs to
allow the installation of a 48/50PG unit onto the existing curb.
INSTALLATION
Follow all local, state, and other applicable codes when
installing the accessory roof curb adapters.
NOTE: All accessory roof curb adapters increase the external
static pressure. The added static pressure must be included
when calculating system requirements. See Table 1.
1. The accessory roof curb adapters have been designed to
fit existing Carrier roof curbs. Before installing, check to
ensure that the dimensions on the existing curb match the
dimensions shown in Fig. 1.
2. Make sure the existing curb and roof structure are capable
of supporting the accessory roof curb adapter and unit.
The adapter curb and unit together will weigh more than
the existing unit.
3. Turn off all gas to the existing unit (if applicable). Shut
off electric power and install lockout tag.
4. Remove existing electrical connections from existing
unit.
5. If existing unit is a gas heat unit, remove gas connection
from existing unit.
6. Some installations may have the existing ductwork at-
tached to the unit instead of the roof curb. If this is the
case, unattach the ductwork from the unit and attach duct-
work to roof curb.
7. Remove the existing HVAC unit from the roof.
8. Reinforce the existing roof curb and roof structure as
required.
9. Install sealing gasket on the top of the curb and duct open-
ings. When installed, the weight of the accessory roof curb
adapter will compress the gasket to seal the joint between
the accessory and the existing curb. Gasket strips must fit
tightly together to leave no gaps for leakage.
Table 1 — Accessory Adapter Curb
Pressure Drop (in. wg)
EXISTING ROOFTOP UNIT EXISTING ROOF CURB ADAPTER CURB USAGE RETROFIT UNIT
48/50DJ,HJ,TF,TFF,TJ,TM004-007
50HJQ,TFQ004-007
CRRFCURB001A00, or
CRRFCURB002A00, or
CRRFCURB022A00*
CRADCURB001A00 48/50PG03-07
48/50DJ,HJ,TF,TFF,TJ,TM008-014
50HJQ,TFQ008-012
CRRBCURB003A00, or
CRRFCURB004A00, or
CRRFCURB023A00*
CRADCURB002A00 48/50PG08-14
48/50HJ015-017
48/50TJ,TM016-028
50HJQ014,016
CRRFCURB010A00 or
CRRFCURB011A00
CRADCURB003A00 48/50PG16
To prevent injuries and rain damage, do not leave roof
opening uncovered. If unit installation is not completed
immediately after adapter curb is installed, provide an ade-
quate temporary cover for the roof opening.
IMPORTANT: Gasketing is critical for water integrity.
Improperly installed gasketing can result in air leaks and
poor unit performance.
ACCESSORY UNIT
PRESSURE DROP
(at 400 cfm/ton)
CRADCURB001A00
48/50PG03 0.12
48/50PG04 0.16
48/50PG05 0.21
48/50PG06 0.27
48/50PG07 0.32
CRADCURB002A00
48/50PG08 0.18
48/50PG09 0.22
48/50PG12 0.28
48/50PG14 0.36
CRADCURB003A00 48/50PG16 0.21
48/50PG03-16
Single-Package Rooftop Units
Roof Curb Adapter Accessory
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - Installation Instructions

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Strany 2 - 15 TON UNITS

2GAS SERVICEPLATE1 - 4 3/16[427](INSIDE)TYP2 3/8[61]0 - 6[152](INSIDE)0 - 7 1/16[179](INSIDE)5 - 7 1/8[1705]3 - 0 15/16[938]1 - 2 [356]OR2 - 0[610

Strany 3

310. Set the accessory curb adapter on top of the existing curb.Make sure openings in accessory adapter curb line upwith the openings in existing roof

Strany 4 - SA — Supply Air

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 1

Komentáře k této Příručce

Žádné komentáře