Carrier 38VBH Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Split-systém klimatizace Carrier 38VBH. Carrier 38VBH Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 23
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
42PQV/38VBH
¥
L
L
O
Y
D
S
R
E
G
I
S
T
E
R
Q
U
A
L
I
T
Y
A
S
S
U
R
A
N
C
E
I
S
O
9
0
0
1
R-410A
INSTALLATION MANUAL
Zobrazit stránku 0
1 2 3 4 5 6 ... 22 23

Shrnutí obsahu

Strany 1 - 42PQV/38VBH

42PQV/38VBH¥LLOYD’SREGISTERQUALITYASSURANCEISO9001R-410AINSTALLATION MANUAL

Strany 2 - 1:1 inverter Heat pump system

42PQV/38VBHGB - 9ENGLISH• The piping can be connected in the four ways indicated by ,,  and .When the piping is connected to points ,  or , rem

Strany 3

42PQV/38VBHGB - 10Routing the drain hose and refrigerantpiping• Tie together the refrigerant pipe, the drain hose, and theelectrical connection cord.•

Strany 4

42PQV/38VBHGB - 11ENGLISHTightening torqueValveFlare nut Valve cap Pressure port cap Valve needle Pressure portWrench mm Nm W

Strany 5

42PQV/38VBHGB - 12Refrigerant connections Pipe Pipe insulation Fastening tape Three-way valve (liquid) Needle valve Valve cap Valve needle All

Strany 6

42PQV/38VBHGB - 13ENGLISHCharge liquid-no gas.Copper tubes during storage.Use tools designed for R-410A higher pressure.Keep inside clean.2-stage vacu

Strany 7

42PQV/38VBHGB - 14Check• Next, check the unit drain system by pouring some water intothe unit drain pan and ensuring that it flows freely through thed

Strany 8

42PQV/38VBHGB - 15ENGLISHMinimum connection wire size (mm2)Model L N R C 1009, 012 1.5 1.5 1.5 1.5 1.5 1.5 LN1IMPORTANT:• Make refrigerant conn

Strany 9

42PQV/38VBHGB - 16Electrical connection for outdoor unit Connecting cable, indoor-outdoor units(field wiring). Mains supply connecting cable(field w

Strany 10

GB - 1742PQV/38VBHENGLISHElectrical connectionsNotes: 1. Outdoor unit is suitable for outdoor installation.2. Wire size shown applies to line length u

Strany 11

42PQV/38VBHGB - 18Pump Down and refrigerant cycleGasLiquid + GasLiquidCooling cycleHeating cycleLegend: Outdoor coil Compressor Check valve Strain

Strany 12

42PQV/38VBH1:1 inverter Heat pump systemENGLISHGB - 1For operation and maintenance instructions of this unit as well as installationinstructions, refe

Strany 13

42PQV/38VBHGB - 19ENGLISHOperating test, address selector and fault codeFault codeOnce a failure occurs with the indoor unit in operation,the green or

Strany 14

42PQV/38VBHGB - 20Table VIII : AccessoriesDescription42PQV/38VBH009 012Wall bracket kit••Active carbon filter and••Passive electrostatic filterNote:If

Strany 15

42PQV/38VBHGB - 21ENGLISHMaintenance and troubleshooting• Mains voltage wrong (too high or too low).• Condenser coil (outdoor or indoor, in case of he

Strany 16

42AP5A54030Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1The manufacturer reserves the right to change any product specifications wi

Strany 17 - 38VBH- 009 - 012

42PQV/38VBHGB - 2General informationUnit installationRead this instruction manual thoroughly before starting theinstallation.• This equipment contains

Strany 18

GB - 342PQV/38VBHENGLISHDimensions and weight Pipe diameter Pipe diameterModel Gas Liquid Gas Liquid(Suction) (Liquid) (Suct

Strany 19

42PQV/38VBHGB - 4DEBACFAMinimum clearances and operating limitsModel 009-012A mm 50B mm 100C mm 400D mm 50E mm 300F mm 400Maximum conditionsoutdoor te

Strany 20

GB - 542PQV/38VBHENGLISHMaterial supplied and system chargeThe following field-supplied items are required to complete the installation.Name Specifica

Strany 21

42PQV/38VBHGB - 6• Fix the unit with locally purchased bolts buried in the block toprevent overturning due to strong gusts of wind.• For heat pump mod

Strany 22

42PQV/38VBHGB - 7ENGLISHExposure to direct sunshine, when unit is operating in coolingmode; always use shutters or shades.Positions too close to heati

Strany 23 - 42AP5A54030

42PQV/38VBHGB - 8Excessive height difference between indoor and outdoor unit (seeTable II "Connections"). Excessive distance between indoor

Komentáře k této Příručce

Žádné komentáře